We repair and replace leaking gaskets, neoprene cone rubbers, bushings, inspection covers, on-load tap changers, conservators and valves.
We repair and refurbish standard and special type Miniature substations.
We also offer purification, regeneration, supply and testing of Transformer Oil.
We supply and test protective relays.
We also supply silica gel and breathers.
Services Listing Include:
· Oil Sampling on Transformers and Mini Sub Stations
· On Site Repairs on Transformers and Mini Sub Stations
· On Site Transformer Oil Purification
· Regeneration of Oil
· On Site Electrical Testing
· On Site Inspection of Transformers and Mini Sub Stations
· Servicing of Ring Main Unit
Due to the ever increasing shortage of mineral transformer oil, it is imperative that we protect our dwindling stocks of this commodity.
Transformer Oil is regenerated (in-situ) in the transformer, as well as in our works. This process removes oxidation by products, moisture, and acidity as well as lightens and brightens the product. Supply and deliver Transformer Oil are supplied in bulk loads delivered in specialized, dedicated road tankers, 1000 liter flow bins or 210 liter drums.
Simply implies the removal of impurities such as moisture, gases and dirt from the oils. Purification however, can be effected on-site and on-load.
It is essential to sample oil correctly. The value of the information gained by testing an oil sample represents the true condition of the oil in the transformer. All our field technicians are trained and equipped with all the tools and equipment necessary to take oil samples.
Testing is done at an independent laboratory and oil sample results and recommendations are given out.
Typical tests carried out during the laboratory analysis of an oil sample include:
· Breakdown voltage (dielectric strength)
· Moisture content
· Dissolved gas analysis
· Oxidation
We primarily service, maintain and repair electrical equipment
which operates in the medium and high voltage sector that is undertaken in-situ.
Work carried out in outdoor substations and as well as indoor substations for
clients in the following sectors of the industry:
· Municipalities
· Large Industry
· Commercial and Retail Operations
· Transnet Group - Metro Rail and Spoornet
Maintenance of Transformers are done on 40MVA to 132 kV as well maintenance on
NEC & AUX Transformers, cleaning of Transformers with High Pressure Washer and
the washing and painting of Transformers.
Oil leaks are done on:
· Breathers
· Bucholz Relay
· Gauge Glasses
· Conservator tank
· Inspection Plates
· H.V & L.V Bushings
· Pressure Relieve Valve
· Bobbins on Transformer
Tap Changers:
· Changing of contacts
· Service of Tap Changers
· Wash and paint of Transformers
· Installing of off-load Tap Switches
Circuit Breakers:
· Testing of the breakers
· Complete Maintenance on VCB’s and OCB’s